Single Channel SIL 3 Digital Output Driver for Solenoid Valves – D5048S
The single channel Loop Powered Digital Output Isolator, D5048S, is suitable for driving solenoid valves, visual or audible alarms to alert a plant operator, or other process control devices in Hazardous Area from a driving signal in Safe Area. It can also be used as a controllable supply to power measuring or process control equipment. Its use is allowed in applications requiring up to SIL 3 level (according to IEC 61508) in safety related systems for high risk industries. The Safety PLC or DCS driving signal powers the field device through the D5048S, which provides isolation and is capable of monitoring the conditions of the line. Short and open circuit diagnostic monitoring, dip-switch selectable and active when input power is present, provides LED indication and NC transistor output signaling.
When fault is detected output is de-energized until normal condition is restored. Line short and open output circuit fault detection is also reflected on the PLC / DCS input circuit providing less than 10 mA consumption. An override input, dip-switch selectable, is provided to permit a safety system to override the control signal. When enabled, a low input voltage always de-energizes the field device regardless of the input signal.
Three basic output circuits are selectable, with different safety parameters, to interface the majority of devices on the market. The selection among the three output characteristics is obtained by connecting the field device to a different terminal block. Mounting on standard DIN-Rail, with or without Power Bus, or on customized Termination Boards, in Safe Area or in Zone 2.
- Output to Zone 0 (Zone 20), installation in Zone 2
- Loop powered for NE loads
- Short and open circuit line diagnostic monitoring with LED, transistor output and current level on input
- Output short circuit proof and current limited
- Three port isolation, Input/Output/Fault
- EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1, EN61326-3-1 for safety system
- In-field programmability by DIP Switch
- ATEX, IECEx Certifications
- Simplified installation using standard DIN-Rail and plug-in terminal blocks, with or without Power Bus, or customized Termination Boards
- 250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier
SIL Level:
D5048S, according IEC 61508 & IEC 61511, is suitable for applications up to safety integrity level SIL 3.
SIL 3 according to IEC 61508 for Tproof = 1 / 2 yrs (10 / 20 % of total SIF).
Contact
- 01706 216667
- 01706 216681
- instruments@whgood.co.uk